TrustFlow-ECG: Reliability-Aware ECG Restoration with Calibrated Risk Estimation

Mohamed Kamel, Tamer Nadeem

eess.SP

Abstract

Electrocardiogram (ECG) restoration models can reduce noise and motion artifacts, but they rarely estimate whether the restored waveform is reliable for downstream analysis. We propose TrustFlow-ECG, a reliability-aware restoration framework that combines a one-step conditional rectified-flow restorer with a lightweight window-level risk predictor. The predictor uses the noisy ECG, restored ECG, and correction residual, then applies validation-set isotonic calibration for selective ECG analysis. We evaluate on MIT-BIH ECG windows corrupted with NSTDB artifacts, powerline interference, and mixed noise across multiple SNRs, with an external 9,675-window PTB-XL stress check without retraining. TrustFlow achieves 0.862 Spearman correlation with true risk and 0.911 AUROC for failure detection, while calibration reduces ECE from 0.0385 to 0.0098. At 80% coverage, selective rejection reduces RMSE from 0.1848 to 0.1345, improves R-peak F1 from 0.8778 to 0.9175, and reduces HR MAE from 6.26 to 4.88 bpm.