Your bids are showing: re-identifying power plants in anonymized market data, and a differentially private alternative
Abstract
ERCOT publishes every generator's hourly offer curve 60 days after the operating day. Market monitors, researchers and traders use these records to study the merit order and check for withholding. PJM publishes the same kind of data with unit names replaced by codes, on the view that masking keeps offers confidential. We test that view on ERCOT data from 2024 to 2026, where names are public and so provide ground truth, by masking the records under PJM's published rules. Public EIA and EPA data match 25% of the masked units we can score (32% of their capacity) to their plant, and 45% fall within the top five guesses. PJM's feed carries the same fields, so we expect masking to fail there too. Publishing exact fuel-group totals instead does not help. An attacker who knows the other units in a group recovers one unit's high-price offers exactly, and an outsider who knows only the target's outage dates reaches a correlation of 0.77, most of it from a few renewable and hydro units that offer at very high prices (0.32 over fossil units). We propose a differentially private release: monthly totals by fuel group and price bin, with Gaussian noise calibrated under zero-concentrated differential privacy so that each unit's whole year of offers is protected. It publishes an unbiased noisy layer and derives a monotone supply curve and shares from it at no extra privacy cost. At per unit-year the market supply curve stays within 11% of the truth, the implied clearing price within \$3.0/MWh, and the attacker's correlation falls to 0.23. Whether an analysis still works depends on one ratio, how much the true quantity varies month to month against the noise, which predicts the accuracy of totals to within 0.05. The clearing price, supply slope and combined-cycle capacity remain usable, but no monthly release, private or exact, can answer questions about single hours or single units.
Create a lesson
Metadata
- Categories
- eess.SY, cs.CR, cs.SY
- Comments
- 14 pages, 14 figures, 2 tables
Related papers
Data Center-Aware Load Pickup in Power System Restoration
Shared title terminologyeess.SYYousef Abudyak, Saleh Sadeghi Gougheri, Mohsen Alizadeh et al.
Voltage Ride-Through-Constrained Power Capping for Large-Scale Data Centers
Shared title terminologyeess.SYJie Zhu, Ye Tian, Yinliang
Thermal-Guided Ensemble Reinforcement Learning for Regime-Adaptive Short-Term GPU Power Forecasting in AI Data Centers
Shared title terminologyeess.SYYuanshuo Zhang, Ying Zhang, Ziying Wang et al.
Data-driven Linearization of Operational Dynamics of Soft Open Points in Power Distribution Networks
Shared title terminologyeess.SYShoaib Hussain, Mostafa Farrokhabadi, Hamidreza Zareipour
Modeling and Stability of Power Systems With Coupled Data Center and Grid Dynamics
Shared title terminologyeess.SYGuido Cavraro
Gaussian Process Data-Driven Hamiltonian for Probabilistic Safe Set Construction
Shared title terminologyeess.SYSeungseok Oh, Junho Kim, Jason J. Choi et al.