Conformal Risk Control for Sentinel-1 Flood Maps under Event Shift and Local Recalibration
Izzath Nisfer, Rahim Iqbal, Shazan Shaheed, Asfi Ahamed, Muhammadu Ilham, Dileesha Manamperi, Thimira Sahan, Sandareka Wickramanayake
Abstract
Conformal Risk Control (CRC) selects a threshold to limit missed labeled positives under exchangeability, but low omission risk can come at the cost of an excessively large flood map. We examine this trade-off with a frozen bi-temporal Sentinel-1 predictor, 403 expert-labeled source groups, and ten evaluable leave-one-event-out folds. At a target risk of 0.10, source-calibrated thresholds produce mean group losses of 0.1726 in Somalia and 0.1985 in Nigeria (four groups). The other eight folds select zero thresholds, labeling every valid pixel as flooded; their excess predicted area is 3.15-20.55 times the labeled positive area. Local threshold recalibration is feasible in 559 of 570 scheduled splits. The equal-event frequency of meeting the observed risk target with a positive threshold is 0.95% at ten labeled groups and 8.00% at twenty, using different predefined event pools. At fifty groups, exploratory recalibration meets both conditions in 24/30 Paraguay splits and none in India or the United States. Labels include permanent water, so the loss does not isolate newly flooded land. The results show why omission risk should be reported alongside mapped area, calibration feasibility, and event-specific outcomes.
Create a lesson
Metadata
- Comments
- 6 pages, 2 figures. Accepted for presentation at IEEE AGERS 2026. This is the submitted version. \c{opyright} 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses
Related papers
PRISM: Perceptual Rate-Controllable Extreme Image Compression with Visual State-Space Models
Shared title terminologyeess.IVMd Adnan Faisal Hossain, Fengqing Zhu
Evaluating Cine and Tagged MRI-to-Speech Synthesis with Complementary Metrics and MRI-Free Controls
Shared title terminologyeess.IVKarlo Vrancic, Fangxu Xing, Jiachen Zhuo et al.
Quality-Control Policies Shape Model Behaviour in Computational Pathology
Shared title terminologyeess.IVMario Parreño Centeno, Yu Guan, Pedro Montero Pavón et al.
A High-Compression Transformer VAE for Efficient and Controllable 3D Medical Image Generation with Diffusion Transformers
Shared title terminologyeess.IVBo Liu, Bingliang Zhang, Yubo Wang et al.
LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising
Shared title terminologyeess.IVFatma Elif Yalçındağ, Mehmet Ozan Ünal, Metin Ertaş et al.
AIstatLab at BraTS-GoAT 2026 Task 3: Quality-Controlled Consensus Pseudo-Labeling and Dense Expert Adaptation
Shared title terminologyeess.IVHeeseung Shin, Changwon Lim