X-ray powerful diagnostics for highly-ionized plasmas: He-like ions
D. Porquet, R. Mewe, J. S. Kaastra, J. Dubau, A. J. J. Raassen
Abstract
The calculations of the ratios of the Helium-like ion X-ray lines from C V to Si XIII are revisited in order to apply the results to density, temperature and ionization process diagnostics of data from high-resolution spectroscopy of the new generation of X-ray satellites: Chandra and XMM-Newton. Comparing to earlier computations, Porquet & Dubau (2000), the best experimental values are used for radiative transition probabilities. The influence of an external radiation field (photo-excitation), the contribution from unresolved dielectronic satellite lines and the optical depth are taken into account. These diagnostics could be applied to collision-dominated plasmas (e.g., stellar coronae), photo-ionized plasmas (e.g., ``Warm Absorber'' in AGNs), and transient plasmas (e.g., SNRs).