Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer
Catherine E. Grant, Gregory Y. Prigozhin, Beverly LaMarr, Mark W. Bautz
Abstract
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.
Create a lesson
Related papers
On binary pulsars and the force of gravity
Davor Palle
Tidal torques. A critical review of some techniques
Michael Efroimsky, James G. Williams
Dynamics of a Spherical Accretion Shock with Neutrino Heating and Alpha-Particle Recombination
Rodrigo Fernández, Christopher Thompson
Asymptotically FRW black holes
J. T. Firouzjaee, Reza Mansouri
Reaction of Accretion Disks to Abrupt Mass Loss During Binary Black Hole Merger
Sean M. O'Neill, M. Coleman Miller, Tamara Bogdanovic et al.
A Gamma-Ray Burst/Pulsar for Cosmic-Ray Positrons with a Dark Matter-like Spectrum
Kunihito Ioka