Direct control of the tunnel splitting in a one-electron double quantum dot
A. K. Huettel, S. Ludwig, K. Eberl, J. P. Kotthaus
Abstract
Quasi-static transport measurements are employed on a laterally defined tunnel-coupled double quantum dot. A nearby quantum point contact allows us to track the charge as added to the device. If charged with only up to one electron, the low-energy spectrum of the double quantum dot is characterized by its quantum mechanical interdot tunnel splitting. We directly measure its magnitude by utilizing particular anticrossing features in the stability diagram at finite source-drain bias. By modification of gate voltages defining the confinement potential as well as by variation of a perpendicular magnetic field we demonstrate the tunability of the coherent tunnel coupling.
Create a lesson
Related papers
Coherent and ultra-low-power EDSR with a flopping-mode spin qubit in germanium
Alexei Orekhov, Wonjin Jang, Pan Zhang et al.
Disorder-induced modulation of the nonlinear Hall effect in Weyl semimetals
Juan A. Cañas, Daniel A. Bonilla, A. Martín-Ruiz
Coplanar Lateral Gating MoS2 on SrTiO3: A Unified Platform for Classical and Quantum Devices
Prasad Muragesh, Manav Murali, Venkatesha Modur Ramachandra et al.
Predictive Structure to Thermal Conductivity Modeling Framework for BEOL Interconnect Stacks in Advanced Technology Nodes Enabled by Extensive Layer Resolved Thermal Measurements
Zifeng Huang, Yiyang Sun, Tianyu Jia et al.
Plasmons in twisted bilayer graphene across dispersive and flat bands
Antonio Palamara, Michele Pisarra, Antonello Sindona
Highly uniform first-electron position in qubit arrays fabricated on dedicated QSOI(R) 300mm commercial platform
Johan Pelloux-Prayer, Elise Prin, Giselle A. Elbaz et al.