High quality factor measured in fused silica

Steven D. Penn, Gregory M. Harry, Andri M. Gretarsson, Scott E. Kittelberger, Peter R. Saulson, John J. Schiller, Joshua R. Smith, Sol O. Swords

gr-qcarXiv:gr-qc/0009035

Abstract

We have measured the mechanical dissipation in a sample of fused silica drawn into a rod. The sample was hung from a multiple-bob suspension, which isolated it from rubbing against its support, from recoil in the support structure, and from seismic noise. The quality factor, Q, was measured for several modes with a high value of 57 million found for mode number 2 at 726 Hz. This result is about a factor 2 higher than previous room temperature measurements. The measured Q was strongly dependent on handling, with a pristine flame-polished surface yielding a Q 3-4 times higher than a surface which had been knocked several times against a copper tube.