The Power Supply System of the CLEO III Silicon Detector
E. von Toerne, J. Burns, J. Duboscq, E. Eckhart, K. Honscheid, H. Kagan R. Kass, D. Larsen, C. Rush, S. Smith, J. B. Thayer
Abstract
The CLEO III detector has recently commenced data taking at the Cornell electron Storage Ring (CESR). One important component of this detector is a 4 layer double-sided silicon tracker with 93% solid angle coverage. This detector ranges in size and number of readout channels between the LEP and LHC silicon detectors. In order to reach the detector performance goals of signal-to-noise ratios greater than 15:1 low noise front-end electronics together with highly regulated low noise power supplies were used. In this paper we describe the low-noise power supply system and associated monitoring and safety features used by the CLEO III silicon tracker.