Computing Volume Bounds of Inclusions by EIT Measurements
Giovanni Alessandrini, Antonio Bilotta, Antonino Morassi, Edi Rosset, Emilio Turco
Abstract
The size estimates approach for Electrical Impedance Tomography (EIT) allows for estimating the size (area or volume) of an unknown inclusion in an electrical conductor by means of one pair of boundary measurements of voltage and current. In this paper we show by numerical simulations how to obtain such bounds for practical application of the method. The computations are carried out both in a 2D and a 3D setting.