The Cryogenic Target for the G0 Experiment at Jefferson Lab
S. D. Covrig, E. J. Beise, R. Carr, K. K. Gustafsson, L. Hannelius, M. -C. Herda, C. E. Jones, J. Liu, R. D. McKeown, R. Neveling, A. W. Rauf, G. Smith
Abstract
A cryogenic horizontal single loop target has been designed, built, tested and operated for the G0 experiment in Hall C at Jefferson Lab. The target cell is 20 cm long, the loop volume is 6.5 l and the target operates with the cryogenic pump fully immersed in the fluid. The target has been designed to operate at 30 Hz rotational pump speed with either liquid hydrogen or liquid deuterium. The high power heat exchanger is able to remove 1000 W of heat from the liquid hydrogen, while the nominal electron beam with current of 40 μA and energy of 3 GeV deposits about 320 W of heat into the liquid. The increase in the systematic uncertainty due to the liquid hydrogen target is negligible on the scale of a parity violation experiment. The global normalized yield reduction for 40 μA beam is about 1.5 % and the target density fluctuations contribute less than 238 ppm (parts per million) to the total asymmetry width, typically about 1200 ppm, in a Q2 bin.
Create a lesson
Related papers
Probing high-momentum components in 16O via zero-degree (p,d) cross-section ratios
FRS Experiment Collaboration, X. Wang, H. J. Ong et al.
Double-differential neutron-induced cross sections on Fe-nat at GANIL-NFS
L. de Arruda, D. Tarrío, X. Ledoux et al.
Event-by-event net-charge fluctuations in pp, OO, Ne-Ne, and Pb-Pb collisions with ALICE at the LHC
Nida Malik
Charge exchange reactions with central and tensor interactions and nuclear matrix elements associated with double-beta-decay neutrinos and astro neutrinos
Hiroyasu Ejiri, Yoritaka Iwata
First Measurement of Compton Scattering on 3He at HIγS
J. Zhou, E. Mancil, M. W. Ahmed et al.
Evolution of high-spin states in neutron-rich 195-202Au isotopes approaching the N=126 shell closure
Y. Cho, Y. H. Kim, A. Navin et al.