Skip to content

Primary versus secondary gamma intensities in 171Yb(nth,gamma)

A. Schiller, A. Voinov, E. Algin, L. A. Bernstein, P. E. Garrett, M. Guttormsen, R. O. Nelson, J. Rekstad, S. Siem

nucl-exarXiv:nucl-ex/0601015

Abstract

The two published literature values [Greenwood et al., Nucl. Phys. A252, 260 (1975) and Gelletly et al., J. Phys. G 11, 1055 (1985)] for absolute primary gamma intensities following thermal neutron capture of 171Yb differ in average by a factor of three. We have resolved this conflict in favor of Greenwood et al. by a measurement of primary versus secondary intensities.