Calibration of Plastic Phoswich Detectors for Charged Particle Detection
D. Fox, D. R. Bowman, G. C. Ball, A. Galindo-Uribarri, E. Hagberg, D. Horn, L. Beaulieu, Y. Larochelle
Abstract
The response of an array of plastic phoswich detectors to ions of has been measured from =12 to 72 MeV. The detector response has been parameterized by a three parameter fit which includes both quenching and high energy delta-ray effects. The fits have a mean variation of with respect to the data.
Create a lesson
Metadata
- Journal
- Nucl. Instrum. Meth. A374 (1996) 63
- Comments
- 17 pages, 5 figures
- Versions
- v1 (10/31/1995), v2 (11/1/1995), v3 (11/2/1995)