We report the development and implementation of an energy feedback system for the MIT/Bates Linear Accelerator Center. General requirements of the system are described, as are the specific requirements, features, and components of the system unique to its implementation at the Bates Laboratory. We demonstrate that with the system in operation, energy fluctuations correlated with the 60 Hz line voltage and with drifts of thermal origin are reduced by an order of magnitude.