Dark resonances as a probe for the motional state of a single ion
C. Lisowski, M. Knoop, C. Champenois, G. Hagel, M. Vedel, F. Vedel
Abstract
Single, rf-trapped ions find various applications ranging from metrology to quantum computation. High-resolution interrogation of an extremely weak transition under best observation conditions requires an ion almost at rest. To avoid line-broadening effects such as the second order Doppler effect or rf heating in the absence of laser cooling, excess micromotion has to be eliminated as far as possible. In this work the motional state of a confined three-level ion is probed, taking advantage of the high sensitivity of observed dark resonances to the trapped ion's velocity. Excess micromotion is controlled by monitoring the dark resonance contrast with varying laser beam geometry. The influence of different parameters such as the cooling laser intensity has been investigated experimentally and numerically.
Create a lesson
Related papers
Optical atomic clocks on all-optical atom chips
Yuri B. Ovchinnikov
Local polarization control of optical tweezer arrays
Xiangkai Sun, Richard Bing-Shiun Tsai, Andrew Winnicki et al.
Response of the near-threshold resonances of the dtμ molecular ion to an effective atomic 2s--2p splitting
Yi Zhang
Disorder-induced nuclear-transition doublet at nominally cubic 229Th sites
Andrei Derevianko
A scanning cavity for large area coherent coupling in atom interferometry
D. O. Sabulsky, Q. Beaufils, A. Bertoldi et al.
A solid-state nuclear clock based on VUV absorption spectroscopy of 229Th
Pengfei Wang, Xu-Fei Yin, Hanlin Wang et al.