GPCALMA: A Tool For Mammography With A GRID-Connected Distributed Database
U. Bottigli, P. Cerello, S. Cheran, P. Delogu, M. E. Fantacci, F. Fauci, B. Golosio, A. Lauria, E. Lopez Torres, R. Magro, G. L. Masala, P. Oliva, R. Palmiero, G. Raso, A. Retico, S. Stumbo, S. Tangaro
Abstract
The GPCALMA (Grid Platform for Computer Assisted Library for MAmmography) collaboration involves several departments of physics, INFN sections, and italian hospitals. The aim of this collaboration is developing a tool that can help radiologists in early detection of breast cancer. GPCALMA has built a large distributed database of digitised mammographic images (about 5500 images corresponding to 1650 patients) and developed a CAD (Computer Aided Detection) software which is integrated in a station that can also be used for acquire new images, as archive and to perform statistical analysis. The images are completely described: pathological ones have a consistent characterization with radiologist's diagnosis and histological data, non pathological ones correspond to patients with a follow up at least three years. The distributed database is realized throught the connection of all the hospitals and research centers in GRID tecnology. In each hospital local patients digital images are stored in the local database. Using GRID connection, GPCALMA will allow each node to work on distributed database data as well as local database data. Using its database the GPCALMA tools perform several analysis. A texture analysis, i.e. an automated classification on adipose, dense or glandular texture, can be provided by the system. GPCALMA software also allows classification of pathological features, in particular massive lesions analysis and microcalcification clusters analysis. The performance of the GPCALMA system will be presented in terms of the ROC (Receiver Operating Characteristic) curves. The results of GPCALMA system as "second reader" will also be presented.
Create a lesson
Related papers
T2 estimation from MOLLI acquisitions
Catarina N Carvalho, Andreia S Gaspar, Rita G Nunes et al.
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler et al.
Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
Michael Douglass, Corey Bridger, Mitchell Herrick et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al.
Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
Yuntao Wang