Fully 3D Monte Carlo image reconstruction in SPECT using functional regions
Z. El Bitar, D. Lazaro, C. Coello, V. Breton, D. Hill, I. Buvat
Abstract
Image reconstruction in Single Photon Emission Computed Tomography (SPECT) is affected by physical effects such as photon attenuation, Compton scatter and detector response. These effects can be compensated for by modeling the corresponding spread of photons in 3D within the system matrix used for tomographic reconstruction. The fully 3D Monte Carlo (F3DMC) reconstruction technique consists in calculating this system matrix using Monte Carlo simulations. The inverse problem of tomographic reconstruction is then solved using conventional iterative algorithms such as maximum likelihood expectation maximization (MLEM). Although F3DMC has already shown promising results, its use is currently limited by two major issues: huge size of the fully 3D system matrix and long computation time required for calculating a robust and accurate system matrix. To address these two issues, we propose to calculate the F3DMC system matrix using a spatial sampling matching the functional regions to be reconstructed. In this approach, different regions of interest can be reconstructed with different spatial sampling. For instance, a single value is reconstructed for a functional region assumed to contain uniform activity. To assess the value of this approach, Monte Carlo simulations have been performed using GATE. Results suggest that F3DMC reconstruction using functional regions improves quantitative accuracy compared to the F3DMC reconstruction method proposed so far. In addition, it considerably reduces disk space requirement and duration of the simulations needed to estimate the system matrix. The concept of functional regions might therefore make F3DMC reconstruction practically feasible.
Create a lesson
Related papers
T2 estimation from MOLLI acquisitions
Catarina N Carvalho, Andreia S Gaspar, Rita G Nunes et al.
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler et al.
Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
Michael Douglass, Corey Bridger, Mitchell Herrick et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al.
Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
Yuntao Wang