Skip to content

Comment on "Test of constancy of speed of light with rotating cryogenic optical resonators"

Michael E. Tobar, Peter Wolf, Paul L. Stanwix

physics.class-pharXiv:physics/0601186

Abstract

A recent experiment by Antonini et. al. [Phys. Rev. A 71, 050101R 2005], set new limits on Lorentz violating parameters in the frame-work of the photon sector of the Standard Model Extension (SME), κe-ZZ, and the Robertson-Mansouri-Sexl (RMS) framework, β-δ-1/2. The experiment had significant systematic effects caused by the rotation of the apparatus which were only partly analysed and taken into account. We show that this is insufficient to put a bound on κe-ZZ and the bound on β-δ-1/2 represents a five-fold improvement not a ten-fold improvement as claimed. (For reply see Phys. Rev. A 72, 066102 (2005) DOI: 10.1103/PhysRevA.72.066102)