Parallel MRI at microtesla fields
V. S. Zotev, P. L. Volegov, A. N. Matlashov, M. A. Espy, J. C. Mosher, R. H. Kraus
Abstract
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at microtesla-range measurement fields. In this work, parallel imaging at microtesla fields is systematically studied for the first time. A seven-channel SQUID system, designed for both ULF MRI and magnetoencephalography (MEG), is used to acquire 3D images of a human hand, as well as 2D images of a large water phantom. The imaging is performed at 46 microtesla measurement field with pre-polarization at 40 mT. It is shown how the use of seven channels increases imaging field of view and improves signal-to-noise ratio for the hand images. A simple procedure for approximate correction of concomitant gradient artifacts is described. Noise propagation is analyzed experimentally, and the main source of correlated noise is identified. Accelerated imaging based on one-dimensional undersampling and 1D SENSE (sensitivity encoding) image reconstruction is studied in the case of the 2D phantom. Actual 3-fold imaging acceleration in comparison to single-average fully encoded Fourier imaging is demonstrated. These results show that parallel imaging methods are efficient in ULF MRI, and that imaging performance of SQUID-based instruments improves substantially as the number of channels is increased.
Create a lesson
Related papers
T2 estimation from MOLLI acquisitions
Catarina N Carvalho, Andreia S Gaspar, Rita G Nunes et al.
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler et al.
Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
Michael Douglass, Corey Bridger, Mitchell Herrick et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al.
Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
Yuntao Wang