μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well DetectorThe PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to provide below tens…Kondo Gnanvo·Dec 10, 2025SaveLearn
A Computational Procedure for Assessing Ic() in Nb3Sn/Bi-2212 Hybrid MagnetsThe critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors…A. D'Agliano, A. V. Zlobin, I. Novitski et al.·Dec 10, 2025SaveLearn
Scintillation response of cryogenic CsI to few-keV and sub-keV nuclear recoilsMonochromatic neutron emissions from photonuclear sources 88Y/Be and 124Sb/Be are employed to obtain the response of pure (undoped) cesium iodide at 80 K. The use of a low-noise,…J. I. Collar, C. M. Lewis, A. Simón et al.·Dec 10, 2025SaveLearn
Machine Learning Optimization of BEGe Detector Event Selection in the VIP ExperimentThe VIP collaboration operates a Broad Energy Germanium detector at the Gran Sasso National Laboratory to measure radiation in the few keV to 100 keV range, aiming to search for spontaneous collapse…Simone Manti, Jason Yip, Massimiliano Bazzi et al.·Dec 10, 2025SaveLearn
Advanced microwave SQUID multiplexer model incorporating readout power effects and Josephson junction inhomogeneitiesWe present an advanced model for describing the readout power dependence of the resonance characteristics of a microwave SQUID multiplexer. Our model proves valid for SQUID screening parameters up to…Martin Neidig, Mathias Wegner, Sebastian Kempf·Dec 10, 2025SaveLearn
Commissioning of a mobile neutron spectrometer for LNGSEnvironmental neutrons are a source of background for rare event searches in underground laboratories. Since the majority of the neutron background comes from the cavern walls due to the intrinsic…Francesco Pompa, Klaus Eitel, Alfredo Davide Ferella et al.·Dec 10, 2025SaveLearn
Non-invasive Techniques for Flow Rate Measurement in Water Pipes: Protocol for a Systematic ReviewAccurate, non-invasive flow measurement is imperative for efficient water resource management and leak detection in distribution systems. Despite the advent of diverse external sensing technologies,…Juan Diego Belesaca, Fabian Astudillo Salinas·Dec 10, 2025SaveLearn
The new truly cylindrical tracker for the ALICE ITS3The ALICE collaboration is preparing an upgrade of the three innermost layers of the current Inner Tracking System (ITS) during the next LHC long shutdown (LS3). The new ITS detector will use…Stefania Perciballi·Dec 9, 2025SaveLearn
Pulse Shape Discrimination for Germanium Detectors using Variational Quantum CircuitsPulse shape discrimination (PSD) is a critical component in background rejection for neutrinoless double-beta decay and dark matter searches using Broad Energy Germanium (BEGe) detectors. To date,…Fabrizio Napolitano·Dec 9, 2025SaveLearn
Study of a small-scale gamma-ray detection system employing Compton scattering with a monolithic CeBr3 crystal and segmented photodetector arrayStudy of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with…Veronika Asova, Galin Bistrev, Simeon Ivanov·Dec 9, 2025SaveLearn
A journey to ITACA: Ion Tracking with Ammonium Cations ApparatusA unique feature of gas xenon electroluminescent time projection chambers (GXeEL TPCs) in 0ββ searches is their ability to reconstruct event topology, in particular to distinguish…J. J. Gómez-Cadenas, L. Arazi, M. Elorza et al.·Dec 9, 2025SaveLearn
Angular emission of scintillators for nuclear fusion diagnosticsAccurate characterization of fast-ion behavior is essential for the safe and efficient operation of nuclear fusion plasmas, as energetic particle losses can degrade plasma performance and damage…M. Rodríguez-Ramos, J. García-Lópeza, M. Videla-Trevina et al.·Dec 9, 2025SaveLearn
Toward an usage of americium-241 for filter calibrationIn nuclear safety and environmental studies, it is necessary to measure the activity of aerosols collected on filters. The calibration of these filters' measurement chains currently involves…G. Dougniaux, B. Sabot, S. Pierre et al.·Dec 9, 2025SaveLearn
Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopyThe first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic,…N. Goyal, F. J. Iguaz, S. Aplin et al.·Dec 9, 2025SaveLearn
Single-step laser patterning and thinning of biocompatible MEMS flow sensorMicro-electro mechanical systems (MEMS) thermal flow sensors are increasingly used for compact, low-power flow monitoring in biomedical applications. However, silicon-based method for sensor…Mohammad Nizar Mohamed Zukri, Muhammad Salman Al Farisi, Yoshihiro Hasegawa et al.·Dec 9, 2025SaveLearn
Self-Error Correcting Method for Magnetic-Array-Type Current Sensors in Multi-Core Cable ApplicationsData-driven methods enable online assessment of error states in magnetic-array-type current sensors, and long-term measurement stability can be enhanced through further self-error correction.…Xiaohu Liu, Keyu Hou, Kang Ma et al.·Dec 8, 2025SaveLearn
Optimization of gain uniformity in thermal bonding Micromegas for the PandaX-III experimentMicro-pattern gas detectors (MPGDs) are widely utilized in physics experiments owing to their excellent spatial resolution and high-rate capabilities. Within the PandaX-III experiment, which aims to…Yunzhi Peng, Yuanchun Liu, Zhiyong Zhang et al.·Dec 8, 2025SaveLearn
Lineshape response of plastic scintillator to pair production of 4.44 MeV gamma'sWe measure the distribution of energy deposited in a 40x88 mm plastic scintillator by e+ e- pair production of 4.44 MeV gamma-rays. We observe the double-escape peak of 3.42 MeV from pair production…Melisa Ozen, John A. Behr, Michelle Khoo et al.·Dec 7, 2025SaveLearn
Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivityRare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due…A. Barresi, D. Chiesa, D. Merli et al.·Dec 6, 2025SaveLearn
Observation of two nuclear recoil peaks induced by neutron capture on Al2O3We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic Al2O3 detector developed by the NUCLEUS collaboration for the detection of reactor…H. Abele, P. Ajello, B. Arnold et al.·Dec 6, 2025SaveLearn
Filters and Redundancies: An Exploration of Novel Coherent Noise Filters for High Energy PhysicsThis work presents radiation-tolerant implementations for the SALSA front-end readout ASIC through redundancy methods applied to two median-finding algorithms designed for coherent noise suppression.…Felipe Costa, Nicolas Guimarães, Guilherme Milani et al.·Dec 5, 2025SaveLearn
Using Open Source EDA Tools in ASICs for HEP: A Mixed ComparisonThis work compares open-source electronic design automation tools with a commercial environment using three representative integrated circuit blocks in the IHP 130 nm open PDK: a common-mode noise…Édney M. V. Freitas, Nicolas Guimarães, Rafael Maria et al.·Dec 5, 2025SaveLearn
GPU acceleration of optical photon propagation in low photon yield applications: Opticks for the Electron Ion ColliderThe bulk of time spent in the simulation of Cherenkov and other scintillation detectors is spent on optical-photon transport, i.e. ray tracing, a task that GPUs are uniquely qualified to perform. We…Gabor Galgoczi, Kolja Kauder, Maxim Potekhin et al.·Dec 5, 2025SaveLearn
Construction and characterization of a seven-chip GridPix X-ray detector for solar axion searchesIn the scope of solar axion searches, detectors which are able to measure low energetic X-rays with high efficiency are required. For this purpose a detector based on the GridPix technology was built…Klaus Desch, Jochen Kaminski, Christoph Krieger et al.·Dec 5, 2025SaveLearn
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBETThe PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based…A. Kallitsopoulou, S. Aune, Y. Angelis et al.·Dec 5, 2025SaveLearn