Characterizing the Delivered Spill Structure of Medical Proton and Carbon-Ion Beams at MedAustron using a High Frequency Silicon Carbide ReadoutMedical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as…Matthias Knopf, Andreas Gsponer, Matthias Kausel et al.·Jul 15, 2025SaveLearn
Practical Software Approach to Digital Pulse ProcessingThis paper presents a practical approach to digital pulse processing, emphasizing simplicity and efficiency. We advocate for a balanced software design, flat data structures, the use of the ROOT C++…Jing Liu·Jul 15, 2025SaveLearn
A highly-compact and ultra-fast homogeneous electromagnetic calorimeter based on oriented lead tungstate crystalsProgress in high-energy physics has been closely tied to the development of highperformance electromagnetic calorimeters. Recent experiments have demonstrated the possibility to significantly…L. Bandiera, V. G. Baryshevsky, N. Canale et al.·Jul 15, 2025SaveLearn
Measurement of photo- and radio-luminescence of thin ThF4 filmsWe conducted measurements on the photo- and radio-luminescence of thin ThF4 films in both the UV and visible ranges. In the UV range, we found that both luminescences are at a similar level as the…Mikhail Osipenko, Carlos de Almeida Carrapico, Dmytro Burdeinyi et al.·Jul 15, 2025SaveLearn
AMBER: Algorithm for Multiplexing spectrometer Background Estimation with Rotation-independenceState-of-the art neutron spectrometers enable simultaneous measurements of high-dimensional datasets, allowing for a large collection rate of dynamic material properties. In this paper, we present…Jakob Lass, Victor Cohen, Benjamín Béjar Haro et al.·Jul 15, 2025SaveLearn
The Study of Thermal Fluctuations in Microwave and Mechanical ResonatorsWe report high-resolution measurements of thermal fluctuations in microwave and mechanical resonators using a dual-channel readout system. The latter comprises a low-noise amplifier, an I/Q-mixer,…Michael T Hatzon, Eugene N Ivanov, Aaron Quiskamp et al.·Jul 15, 2025SaveLearn
Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometersThe scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present…J. C. Groh, Z. Ahmed, J. Austermann et al.·Jul 15, 2025SaveLearn
A New Method for the Discovery of the Distant Exoplanets II: Question of Signal-to-Noise RatioExoplanets with a long orbital period are difficult to discover by extant methods. Our first publication (Lerner, P., A. Mayer, T. E. Sullivan. 2023. A new method for the discovery of the distant…Peter B. Lerner·Jul 14, 2025SaveLearn
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counterA barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used…Y. K. Tanaka, R. Sekiya, K. Itahashi et al.·Jul 14, 2025SaveLearn
Optimization of a cosmic muon tomography scanner for cargo border control inspectionThe past several decades have seen significant advancement in applications using cosmic-ray muons for tomography scanning of unknown objects. One of the most promising developments is the application…Z. Zaher, H. Lay, T. Dorigo et al.·Jul 14, 2025SaveLearn
Self-Powered Triboelectric Sensing System for Gait-Based Physiological and Psychological Assessment in Track and FieldWearable sensors are critical components in smart sports systems for real-time monitoring of athletic performance, physiological conditions, and psychological states. In this work, a sodium…Tiehuai Liang, Dongyuan Wei, Qi Zhang·Jul 14, 2025SaveLearn
CRYSP: a Total-Body PET based on cryogenic cesium iodide crystalsTotal Body PET (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical…S. R. Soleti, P. Dietz, R. Esteve et al.·Jul 13, 2025SaveLearn
The calibration house in JUNOAs an auxiliary system within the calibration system of the Jiangmen Underground Neutrino Observatory, a calibration house is designed to provide interfaces for connecting the central detector and…J. Hui, R. Li, Y. Wu et al.·Jul 12, 2025SaveLearn
CycleGAN-Driven Transfer Learning for Electronics Response Emulation in High-Purity Germanium DetectorsHigh-Purity Germanium (HPGe) detectors are a key technology for rare-event searches such as neutrinoless double-beta decay (0ββ) and dark matter experiments. Pulse shapes from…Kevin Bhimani, Julieta Gruszko, Morgan Clark et al.·Jul 12, 2025SaveLearn
Muon Signal Charge in the Underground Muon Detector of AugerPrimeThe Underground Muon Detector of the Pierre Auger Observatory features a calorimetric detection mode that estimates the number of muons based on signal charge measurements. This contribution provides…Marina Scornavacche·Jul 11, 2025SaveLearn
A Neutron Sensitive Detector Using 3D-Printed ScintillatorsThis work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing…Adam Barr, Cinzia da Vià, Mosst Tasnim Binte Shawkat et al.·Jul 11, 2025SaveLearn
Spatial and Temporal Evaluations of the Liquid Argon Purity in ProtoDUNE-SPLiquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP)…DUNE Collaboration, S. Abbaslu, A. Abed Abud et al.·Jul 11, 2025SaveLearn
Measurement of the Liquid Argon Scintillation Pulse Shape Using Differentiable Simulation in the Coherent CAPTAIN-Mills ExperimentThe Coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and Beyond Standard Model physics signatures. Two hundred 8-inch…A. A. Aguilar-Arevalo, S. Biedron, J. Boissevain et al.·Jul 10, 2025SaveLearn
First Event-by-Event Identification of Cherenkov Radiation from Sub-MeV Particles in Liquid ArgonThis Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon (LAr) detector by the Coherent CAPTAIN-Mills (CCM)…A. A. Aguilar-Arevalo, S. Biedron, J. Boissevain et al.·Jul 10, 2025SaveLearn
Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection ChamberThe DarkSide-20k dark matter direct detection experiment will employ a 21 m2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC).…F. Acerbi, P. Adhikari, P. Agnes et al.·Jul 9, 2025SaveLearn
A Prototype Hybrid Mode Cavity for Heterodyne Axion DetectionIn the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the…Zenghai Li, Kevin Zhou, Marco Oriunno et al.·Jul 9, 2025SaveLearn
Lifetime study of the ColdADC for the Deep Underground Neutrino ExperimentColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far…Wenjie Wu, Benjamin Jargowsky, Yiwen Xiao et al.·Jul 9, 2025SaveLearn
Amplitude Walk in Fast Timing: The Role of Dual ThresholdsWe apply lessons from fast timing detector R\&D to strategies for initial calibration of large timing arrays at future colliders. Detector R\&D often benefits from detailed information about the…Sebastian White, Alessio Boletti·Jul 8, 2025SaveLearn
Quantitative U/Th deposition and cleanliness control strategies in the JUNO site airThe Jiangmen Underground Neutrino Observatory (JUNO) employs a 20 kt liquid scintillator (LS) detector located 700 m underground. To meet its physics objectives, the LS must achieve an ultra-low…Jie Zhao, Chenyang Cui, Yongpeng Zhang et al.·Jul 8, 2025SaveLearn
The CMS Phase-2 Fast Beam Condition Monitor prototype test with beamThe Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new,…G. Auzinger, H. Bakhshiansohi, A. E. Dabrowski et al.·Jul 7, 2025SaveLearn