Sensitivity of silicon-to-water dose conversion and Bragg-peak metrics to stopping-power datasets in proton dosimetry
F. Matias, J. M. B. Shorto, P. de Vera, R. Garcia-Molina, I. Abril, T. F. Silva, J. Pereira, H. Yoriyaz
Abstract
Accurate proton dosimetry requires consistent stopping-power data for detector-to-water conversion and Monte Carlo radiation transport. We quantify the sensitivity of water-to-silicon stopping-power ratios, converted dose-to-water distributions, and Bragg-peak metrics to the stopping-power dataset for a 67.5 MeV pristine proton beam in water. PHITS simulations used SRIM-2013, PSTAR/NIST, ATIMA, and TDDFT-Penn stopping powers up to 10 MeV, together with a common SBETHE-based extension at higher energies. The water-to-silicon stopping-power ratio showed relative entrance-to-distal variations of 17.40%22.10%. Conversion of normalized PTW silicon-diode percentage-depth-ionization data yielded relative percentage-depth-dose curves with a common maximum at 36.86 mm, consistent with the experimental Bragg-peak depth of (36.81 0.15) mm. The converted curves were approximately 3% below the reference throughout the entrance and plateau regions, while deviations of up to 2.1% occurred near the Bragg peak. Direct PHITS calculations predicted Bragg-peak depths of 36.57536.675 mm; only the TDDFT-Penn result lay within the quoted experimental uncertainty. These results show that stopping-power treatment affects the magnitude of the converted dose more strongly than the Bragg-peak position does, and that it should be harmonized or explicitly included in uncertainty budgets for proton-beam calibration, commissioning, quality assurance, and Monte Carlo validation.
Create a lesson
Related papers
Proposal of a consistent value for the mean excitation energy of liquid water using advanced modeling, detailed simulations and precission proton Bragg curves
Shared title terminologyphysics.med-phPablo de Vera, Isabel Abril, Flávio Matias et al.
DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT
Shared title terminologyphysics.med-phEleftherios Tzanis, Antonios Tzortzakakis, Michail E. Klontzas
Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy system
Shared title terminologyphysics.med-phToghrul Alakbarzade, Emir Musa Olgun, Yuan James Rao et al.
Towards in vivo photon dosimetry using radiation-sensitive mixed-core ultrasound phase-change contrast agents
Shared title terminologyphysics.med-phBram Carlier, Reza Bahrami Gorji, Qingyuan Tan et al.
From Radiotherapy Dataset to Cherenkov Dose Map: A Digital Linac Monte Carlo Simulation Pipeline
Shared title terminologyphysics.med-phXianghuan He, Changyu Sun, Andy N. Wiles et al.
A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring
Shared title terminologyphysics.med-phNico Frederic Brosda, Stephane Higueret, Nicolas Arbor et al.