Liver Metastasis Detection at Reduced Radiation Dose: Diagnostic Evaluation of a Novel Organ-Level Tube Current Modulation Method
Maria Jose Medrano, Sen Wang, Kaylee W. Fang, Jennie Cao, Liyan Sun, Luyao Shen, Andy Shon, Luke Yoon, Grant M. Stevens, Adam S. Wang, Justin R. Tse
Abstract
Objective: To evaluate retroOpt, a novel organ-level tube current modulation (TCM) method that minimizes effective radiation dose while preserving diagnostic image quality for liver metastasis detection. Methods: In this retrospective, IRB-approved study, 22 patients with 68 liver lesions (38 malignant, 30 benign) underwent portal venous phase contrast-enhanced chest-abdomen-pelvis CT. Using projection-domain noise emulation, five series were generated per patient: original full dose (Orig-100), uniform dose reduction to 40% (UD-40) and 60% (UD-60) of the original effective dose, and organ-level TCM at the same levels (Opt-40, Opt-60). Three abdominal radiologists independently detected and classified lesions and rated image quality (5-point Likert). Per-lesion sensitivity was compared by McNemar test. Malignant lesion-size thresholds for 50% and 90% sensitivity (x50, x90) were estimated by logistic regression. Image quality was compared by Wilcoxon signed-rank test. Results: At the 60% level, Opt-60 achieved mean malignant lesion sensitivity comparable to full-dose CT (82% vs 80%) and exceeded uniform reduction (67%). At the 40% level, Opt-40 improved mean sensitivity over UD-40 from 52% to 68%. Mean all-lesion sensitivity rose from 54% (UD-40) to 64% (Opt-40) and from 65% (UD-60) to 77% (Opt-60), remaining comparable to full dose (76%). All optimized-versus-uniform differences were significant (p <= 0.003). Opt-60 lesion-size thresholds closely matched Orig-100 (x50 3.3 vs 3.7 mm; x90 15.7 vs 16.8 mm). Median Opt-60 image quality ranged from 3 to 4.5 across readers. Conclusions: Organ-level TCM preserved liver metastasis detection at 60% of the original effective dose, outperforming uniform dose reduction. Task-specific organ-level dose optimization may enable greater CT dose reduction than uniform strategies for patients requiring repeated metastasis surveillance.
Create a lesson
Related papers
Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose
Shared title terminology · Parmita Mondal, Rickey Carter, Andrew D Missert et al.
Evaluation of Image Noise from Computed Tomography in an Organ-Specific Anthropomorphic Phantom
Shared title terminology · Lucas McCullum, Mojtaba Zarei, Andy Tsai et al.
MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection
Shared title terminology · Omar Nusrat
Evaluation of the Exradin A30 Parallel Plate Ion Chamber as a Reference Dosimeter in Ultra-High Dose Rate (UHDR) Electron Beams
Shared title terminology · Mervat Alharbi, Kevin Liu, Brian Hooten et al.
A novel strategy for achieving a low-field lightweight permanent MRI magnet system with good magnetic field homogeneity and low eddy current
Shared title terminology · Jingzhi Han, Jiangqian Guo, Peng Shen et al.
Artificial Intelligence Across the Cardiac Amyloidosis Diagnostic and Management Pathway: From Single-Modality Detection to Multimodal Clinical Integration
Shared title terminology · Diana Shadibaeva, Rochak Dhakal, Kui Zhang et al.