Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
Jinyang Yu, Oliver Gödicke, Frederik B. Laun, Obada T. Alhalabi, Iris A. Kohler, Jürgen Hesser, Sandro M. Krieg, Bogdana Suchorska, Heinz-Peter Schlemmer, Mark E. Ladd, David Bonekamp, Johann M. E. Jende, Tristan A. Kuder
Abstract
Purpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting. Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference. Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster. Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.
Create a lesson
Related papers
Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning
Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty et al.
Sparse Delta Integration method for the calculation of spatiotemporal pressure fields of arbitrary ultrasound transducer geometries
Deyver E. Rivera, Charlie Demene, Mickael Tanter
Adapting the TG-43 formalism for use in Diffusing alpha-emitters Radiation Therapy
Guy Heger, Lior Epstein, Lior Arazi
Evaluation of the Exradin A30 Parallel Plate Ion Chamber as a Reference Dosimeter in Ultra-High Dose Rate (UHDR) Electron Beams
Mervat Alharbi, Kevin Liu, Brian Hooten et al.
Clustering of anterior corneal surface shapes in normal adults
Hala Bouazizi, Isabelle Brunette, Jean Meunier
Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis
Cyrus Mexon Evrard Djindot, Faliang Liu, Sylvain Laborde et al.