A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging
Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li
Abstract
Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of NcT=1, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~μW, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for NcT=2 and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.
Create a lesson
Related papers
Unimodality and Radial Monotonicity of the Magnetic Resonance Fingerprinting T1/T2 Matching Objective
Ze Wang
Physics-Assisted Deep Learning Denoising for Stabilized IMPULSED dMRI Microenvironment Parameter Fitting
Wen Li, Yan Dai, Arely Perez Rodriguez et al.
Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
Jinyang Yu, Oliver Gödicke, Frederik B. Laun et al.
Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning
Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty et al.
Sparse Delta Integration method for the calculation of spatiotemporal pressure fields of arbitrary ultrasound transducer geometries
Deyver E. Rivera, Charlie Demene, Mickael Tanter
Adapting the TG-43 formalism for use in Diffusing alpha-emitters Radiation Therapy
Guy Heger, Lior Epstein, Lior Arazi