BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction
Chen Cheng, Michael Ferraro, James Grover, David E J Waddington, Emily Hewson
Abstract
To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation arranged as channels, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated using a conditional GAN with a SwinUNETR generator and a PatchGAN discriminator. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.
Create a lesson
Related papers
P^2-Gaussian: Prior-Driven and Projection-Guided Gaussian Splatting for Sparse-View Cone-Beam CT Reconstruction
Shared title terminology · Jinqiu Xia, Jianhui Ma, Bin Ouyang et al.
Emission-associated energy deposition and Cherenkov-dose proportionality in megavoltage photon beams
Shared title terminology · Xianghuan He, Yao Hao, Changyu Sun et al.
PyDoseRT Photon: Physics-Guided Pencil-Beam Dose Calculation with Neural Priors and Residual Correction for CT and MRI
Shared title terminology · Attila Simkó, Lukas Zimmermann, Hermann Fuchs et al.
PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation
Shared title terminology · Lukas Zimmermann, Hermann Fuchs, Attila Simkó et al.
Evaluation of the Exradin A30 Parallel Plate Ion Chamber as a Reference Dosimeter in Ultra-High Dose Rate (UHDR) Electron Beams
Shared title terminology · Mervat Alharbi, Kevin Liu, Brian Hooten et al.
Focal-point scanning for dose delivery and optimization with focused laser-accelerated very-high-energy electron beams
Shared title terminology · Zhiyuan Guo, Yifei Pi, Junwei Zhou et al.