P^2-Gaussian: Prior-Driven and Projection-Guided Gaussian Splatting for Sparse-View Cone-Beam CT Reconstruction
Jinqiu Xia, Jianhui Ma, Bin Ouyang, Xiaoyan Huang, Yuan Xu, Zun Piao
Abstract
Sparse-view cone-beam computed tomography (CBCT) reconstruction reduces imaging dose and scan time, but severe angular undersampling makes the inverse problem highly ill-posed. Existing 3D Gaussian Splatting (3DGS) methods initialize Gaussian primitives from Feldkamp-Davis-Kress (FDK) reconstructions that are contaminated by streak artifacts. The limited angular coverage also leaves the Gaussian parameters underconstrained, producing needle-like artifacts. We propose P2-Gaussian, a prior-driven and projection-guided 3DGS framework. In this framework, a latent rectified flow model, Sparse2Prior, first restores the artifact-corrupted FDK volume into an anatomical prior in approximately 5 s. Gaussian primitives are then initialized from this prior in a tissue-adaptive manner, which yields a compact representation with 62%-65% fewer optimized primitives than random sampling. During optimization, virtual projections synthesized at intermediate angles between the measured projections are activated in rotation, while measured projections remain dominant in the objective function. Experiments on 5, 10 and 20 measured views showed that the proposed P2-Gaussian achieved the highest PSNR and SSIM among all methods. Compared with the optimization-based Gaussian baseline, our method increases PSNR by 5.98, 4.25 and 2.49 dB and accelerates reconstruction by 2.6-3.0 times. These results indicate that coupling a learned anatomical prior with measurement-constrained Gaussian optimization is effective for sparse-view CBCT reconstruction. Code is publicly available at: https://github.com/Ballbo5354/P-2-Gaussian.
Create a lesson
Related papers
Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT
Shared title terminology · Sungho Yun, Seungryong Cho
Bridging cone-beam CT and MRI to stopping power ratio maps: a modality-agnostic Brownian bridge approach to support robust adaptive proton therapy
Shared title terminology · Yuhao Yan, Qisheng He, Minglei Kang et al.
Cone-beam artifact reduction in Gamma Knife CBCT images using a line-arc-line scan trajectory
Shared title terminology · Alexandra Alain-Beaudoin, Håkan Nordström, Luc Beaulieu et al.
Non-circular scan trajectories for reducing cone-beam artifacts in Gamma Knife CBCT images: a simulation study
Shared title terminology · Alexandra Alain-Beaudoin, Håkan Nordström, Luc Beaulieu et al.
BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction
Shared title terminology · Chen Cheng, Michael Ferraro, James Grover et al.
PyDoseRT Photon: Physics-Guided Pencil-Beam Dose Calculation with Neural Priors and Residual Correction for CT and MRI
Shared title terminology · Attila Simkó, Lukas Zimmermann, Hermann Fuchs et al.