High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scanner
Jerome J. Maller, Patricia Lan, Sherry Huang, Chitresh Bhushan, Xinzeng Wang, Ante Zhu, Vincent A. Magnotta
Abstract
Data from conventional diffusion tensor imaging (DTI) using single-shot echo planar imaging (SS-EPI) acquisition are substantially influenced by magnetic field inhomogeneities (delta B0), which result in image distortion and signal dephasing. Multi-shot EPI can mitigate the delta B0-induced artifacts but at the cost of increased scan time. Recent brain tissue-selective, dynamic slice-by-slice B0 shimming techniques have demonstrated effective reduction of local delta B0 in the brain. When combined with DTI utilizing an echo-planar imaging (EPI) read-out, image distortion and signal dephasing are significantly reduced. The purpose of our study was to assess the impact of DTI with dynamic slice-by-slice B0 shimming technique (DySiBo) on white matter (WM) tractography. We retrospectively analyzed DTI datasets using SS-EPI and Multi-shot EPI with 2 shots (MS-2shot-EPI) readout at two spatial resolutions (1x1x2mm3 and 2x2x2mm3) with and without DySiBo. WM tractography was generated and inspected to examine the impact upon regions typically affected by delta B0-induced artefacts. We found more WM streamlines were generated in the DTI datasets with DySiBo in regions conventionally impacted by delta B0-induced in EPI images, including the brainstem, temporal and frontal lobes. DySiBo substantially improved the generation of WM streamlines in DTI-based tractography at both in-plane resolutions. In conclusion, DySiBo in conjunction with DTI requiring 10 diffusion tensor directions is sufficient to generate data with high enough SNR and angular resolution to resolve crossing fibers and produce high quality WM tractography in brain regions typically affected by susceptibility-induced artefacts. This has implications for quantitative WM microstructural indices and clinical evaluation of WM tracts in patients.
Create a lesson
Related papers
Diffusion Posterior Sampling for Mitigation of Spatially-Variant System Blur in Ultra-High-Resolution CT of Trabecular Bone
Shared title terminology · T. Ye, G. Shi, A. Sivakumar et al.
Towards Sustainable Magnetic Resonance Imaging: Insights from long-term, high-resolution energy recordings across an entire scanner fleet
Shared title terminology · Florian Leonhard Raab, Fiona Mankertz, Nour Maalouf et al.
High-Resolution 3D Micro-CT Database of Transcranial Magnetic Stimulation (TMS) Coils for More Accurate Modelling, Technology Benchmarking, and Progress in Coil Design
Shared title terminology · Maryam Farahmandrad, Max Koehler, Mahdi Bayati et al.
Sensitivity of diffusion MRI to white matter pathology: a comparison between ROI-based effect size and TBSS analysis under different diffusion protocols, field strengths and post-processing strategies
Shared title terminology · Evgenios N. Kornaropoulos, Theodor Rumetshofer, Anna Gard et al.
Phase-Constrained Self-Supervised Reconstruction and Denoising for Ultra-High-Resolution MRI
Shared title terminology · Juan Liu, Zhuoheng Liu, Hongbo Wu et al.
High resolution 3D localization of ultrasound sparse sources using a SAGE algorithm
Shared title terminology · Sophie V. Heymans, François Rottenberg, Tatiana Gelvez-Barrera et al.