Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment
Chemseddine Ananna, Gabriella Cataldi, Davide D'Angelo, Giulia D'Imperio, Maria Luisa De Giorgi, Giuseppe Di Carlo, Attilio Di Giacinto, Marcella Diemoz, Aldo Ianni, Sana Gul Khattak, Edoardo Martinenghi, Alessandro Miccoli, Marcin Misiaszek, Daniele Montanino, Valerio Pettinacci, Lidio Pietrofaccia, Shahram Rahatlou, Krzysztof Szczepaniec, Claudia Tomei, Valerio Toso, Chiara Vignoli, Samina Zuhra, Francesco Ferella, Stefano Nisi
Abstract
Direct dark matter detection with NaI(Tl) scintillators requires ultra-low-background materials. Silicone optical pads can couple NaI(Tl) crystals to photomultiplier tubes (PMTs) if they provide adequate optical transmission and radiopurity. We characterize four candidate materials for the SABRE-North experiment: commercial EJ-560, used as a reference, and three materials produced at the University of Salento (SYLGARD 184, EGel 3002 A/B, and a hybrid formulation) using different catalyst ratios and curing conditions, yielding ten samples in total. Optical transmittance was measured from 310 to 850 nm by UV/Vis/NIR spectrophotometry. Radiopurity was assessed at the STELLA facility at LNGS using high-purity germanium (HPGe) γ-ray spectrometry and, for EJ-560, high-resolution ICP-MS. At the 410 nm NaI(Tl) emission peak, EJ-560 shows an absorbance coefficient of 0.0640.017 mm-1. The best locally produced samples reach 0.0970.015 and 0.0930.014 mm-1 for SYLGARD 184 with a 10:2 base-to-catalyst ratio cured at room temperature and at 40, respectively, 0.1250.015 mm-1 for EGel 3002 with a 2B:A ratio cured at 40, and 0.1060.014 mm-1 for the hybrid 10:1 EGel A:CataSYL formulation cured at room temperature. EJ-560 exhibits detectable 232Th-chain activity at about 1.8 mBq/kg and the highest 40K activity, (12020) mBq/kg. The locally produced materials show no detectable Th-chain contamination but exhibit 226Ra activities of about 2.3 mBq/kg and lower 40K levels. No single material is optimal across all criteria. Additional ICP-MS screening, HPGe measurements of cured pads, and direct NaI(Tl)-PMT light-yield tests are required for a conclusive SABRE-North material selection.
Create a lesson
Related papers
Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)
B. Gerke, V. Hannen, S. Peters et al.
Beam Spill Structure Measurements at CEE Using the T0 Detector
Shuaike Lv, D. Hu, Dayu Yin et al.
CNN-based Position Reconstruction for the T0 Detector in the HIRFL-CSR External-target Experiment
Shuai-Ke Lv, D Hu, M Shao et al.
Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout
Jiawei Bian, Zaihong Yang, Qite Li et al.
Cavity Characterization for the Princeton Axion Search
Nate Otto, Jianyang Fu, Joelle-Marie Begin et al.
First demonstration of 50\,ps four-dimensional vertex reconstruction with the Timepix4 beam telescope
David Bacher, Kazu Akiba, Martin van Beuzekom et al.