A software tool for parametric collimator creation for linac-based preclinical irradiation studies
Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, M. Ramish Ashraf, Lawrie Skinner, Edward Elliot Graves, Billy W. Loo, Stavros Melemenidis
Abstract
Designing custom Cerrobend collimators for linac-based preclinical electron irradiation is labor intensive and susceptible to design inconsistencies. We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold, collimator shell, Cerrobend holder, and beam degrader. Two designs were fabricated and characterized: a 4.0 x 1.5 cm bilateral lung collimator centered on the central axis and a 1.5 x 1.5 cm unilateral lung collimator with a 7.5 mm jig offset, each with a 15 mm thick Cerrobend collimator and a 10 mm PLA degrader. Kilovoltage planar images were used to assess aperture geometry and casting uniformity. Radiochromic film was used to measure full width at half maximum (FWHM) and 80%-20% penumbra under conventional and ultra high dose rate (UHDR) electron delivery on a Varian TrueBeam, and off axis leakage was measured with an ionization chamber at conventional dose rate. The cast Cerrobend apertures deviated by less than 0.2 mm from their specified designs. FWHM values were within 3% of the nominal field dimensions, and penumbra ranged from 0.73 to 1.05 mm under conventional and UHDR delivery. Crossline leakage 2 cm beyond the collimator edge was below 2% for both collimators at conventional dose rate. Parametric collimator generation standardized digital design inputs for the two evaluated rectangular linac-based electron fields. Further work will assess specimen-level dosimetry, additional aperture geometries, and Monte Carlo integration.
Create a lesson
Related papers
Subwavelength registration of skull-compensating acoustic holograms via nonlinear parametric array feedback
Shared title terminology · Pradosh Pritam Dash, Costas D. Arvanitis
From Radiotherapy Dataset to Cherenkov Dose Map: A Digital Linac Monte Carlo Simulation Pipeline
Shared title terminology · Xianghuan He, Changyu Sun, Andy N. Wiles et al.
Open-source Software and Pipelines for Generalizable and Reproducible EEG Analysis: An Overview
Shared title terminology · Takfarinas Medani, Raymundo Cassani
Direct Production of Ultra-High Radioisotopic Pure ^{64}Cu from Natural Zinc Metal via D-D Fusion Narrowband Fast Neutron Source Irradiation
Shared title terminology · Jeremy M. C. Brown, Mantas Grigalavicius, Tibor Gilinger et al.
Separating active irradiation from passive outcome learning in radiotherapy: a finite-model computational benchmark
Shared title terminology · Yuntao Wang
A Guidewire Trajectory Generation Tool for Interventional MRI Simulations
Shared title terminology · Fatima Ben Haj, Jeffrey Hand, Shaihan Malik et al.