Subwavelength registration of skull-compensating acoustic holograms via nonlinear parametric array feedback
Abstract
Realizing the potential of optimized acoustic holograms for applications like transcranial ultrasound requires sub-wavelength alignment accuracy (less than 1.5 mm at 1 MHz), which is difficult to achieve with current non-MRI optical neuro-navigation methods. To address the critical challenge of alignment, we leverage the parametric array (PA) signal as an alignment surrogate, a highly penetrative, low-frequency difference wave generated by the nonlinear mixing of two primary high-frequency beams. Simulations show that a misaligned skull-compensating lens increases the primary acoustic energy within the skull bone (volumetric energy trapping), which strengthens the nonlinear source of the PA signal. We also tested whether shear-mode conversion in bone contributes: 2D elastic simulations showed only a small (3-5%) increase in shear-type motion with misalignment, and the transmitted ex vivo bursts did not lengthen as a shear path would require. Pseudo-sound and microbubble artifacts were examined and found unlikely to explain the signal, consistent with the PA signal arising from the intrinsic nonlinearity of the bone. Minimizing this PA signal yields a noninvasive real-time feedback mechanism that achieves sub-wavelength alignment accuracy, outperforming standard neuronavigation. Our findings present a robust framework that supports the design of simple, economical, and high-performance transcranial ultrasound systems for high-precision neuro-interventions.
Create a lesson
Related papers
MRI-Free CT-to-Ultrasound Skull Registration in Transcranial Focused Ultrasound using CMUT based Integrated Therapeutic and Imaging Arrays
Shared title terminology · Reza Pakdaman Zangabad, Sai Vikas Satyanarayana, Costas D. Arvanitis et al.
ReCoFlow-MRI: Few-Step Conditional Flow Matching for GNL-Induced Nonlinear MRI Reconstruction
Shared title terminology · Qidi Luo, Hongli Chen, Jialiang Zhang et al.
Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants
Shared title terminology · U-Wai Lok, Jingke Zhang, Jingyi Yin et al.
Simultaneous 3D acoustic modulation and imaging of proton-induced nanodroplet vaporization for proton therapy monitoring
Shared title terminology · Sophie V. Heymans, Bram Carlier, Marcus Ingram et al.
Photoacoustic imaging of human brain function through intact adult skulls
Shared title terminology · Yilin Luo, Rui Cao, Manxiu Cui et al.
A software tool for parametric collimator creation for linac-based preclinical irradiation studies
Shared title terminology · Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi et al.