Simulation analysis of a direct/indirect conversion dual-layer X-ray detector for early identification of coronary artery calcium
Akyl Swaby, Linxi Shi, Kaitlin Hellier, Adam S. Wang, Shiva Abbaszadeh
Abstract
Coronary artery calcification (CAC) is a strong predictor of future cardiovascular events, and CAC burden is commonly used to stratify patient cardiovascular risk. Although CAC is typically quantified using computed tomography, routine chest radiography offers an opportunity for lower-dose, widely available opportunistic screening. Single-exposure dual-energy chest radiography using multilayer flat-panel detectors can generate low- and high-energy images without motion artifacts and provide material decomposition parameters, including calcification density. In this work, we investigate a direct/indirect dual-layer detector consisting of an amorphous selenium (a-Se) direct-conversion top layer and a cesium iodide scintillator-based indirect-conversion bottom layer for enhanced visualization of small CAC. A cascaded linear systems model (CLSM) simulated task-based detectability for a 1 mm calcification embedded in soft tissue. A complementary image-domain contrast-to-noise ratio (CNR) analysis using CT-derived patient anatomy with inserted 1 mm calcifications evaluated CNR as a function of a-Se thickness and dual-energy weighting factor. The CLSM analysis revealed peak task-based detectability at an a-Se thickness of 500-550 um and a tissue-cancellation weighting factor of 1.08. Detectability remained within a few percent of this maximum across a broad range of a-Se thicknesses (300-1000 um). The image-domain CNR analysis yielded maximum CNR at 300 um a-Se and weighting factor of 0.93, with a smaller range of 200-500 um giving acceptable CNR. These results indicate that near-equal weighting of the two detector layers improves anatomical-noise suppression and CAC conspicuity, while a 300 um a-Se top layer provides a practical design compromise between detectability, operating voltage, and manufacturability.
Create a lesson
Related papers
Toward opportunistic coronary artery calcium assessment from dual-layer dual-energy chest radiography using deep learning: a simulation study
Shared title terminology · Linxi Shi, Akyl Swaby, Kaitlin Hellier et al.
Dual-energy cardiac DSA imaging using a dual-layer flat-panel detector: in vivo validation study
Shared title terminology · Yuhang Tan, Jiongtao Zhu, Xin Zhang et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
Shared title terminology · C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Evaluation of attenuation-based simulated X-ray images for image-guided radiotherapy
Shared title terminology · Hannah Jungreuthmayer, Julius Arnold, Andreas Renner et al.
Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector
Shared title terminology · Michelle K. Croughan, Timur E. Gureyev, Jane Fox et al.
A scalar arterial input function does not uniquely determine the perfusion residue: Theory and phantom MRI
Shared title terminology · Yuyang Gan, Dominick Romano, Maneesh John et al.