A scalar arterial input function does not uniquely determine the perfusion residue: Theory and phantom MRI
Yuyang Gan, Dominick Romano, Maneesh John, Renjiu Hu, Qihao Zhang, Benjamin Weppner, Alexey V. Dimov, Pascal Spincemaille, Yi Wang
Abstract
Purpose: To relate the residue function of tracer kinetic models to blood velocity and cross-sectional tracer distributions at the arterial inlet, and show that a cross-sectionally averaged arterial input function (AIF) does not uniquely determine the residue. Theory and Methods: For steady laminar flow without radial diffusion, the residue function referenced to the cross-sectionally averaged inlet AIF was analytically derived from the velocity and inlet tracer distributions. In a straight tube with parabolic flow, two nonnegative inlet profiles sharing one measured AIF were compared for gamma-variate and rectangular arterial spin labeling (ASL) inputs. A straight-tube phantom was imaged at 3 T during gadolinium bolus passage, with uniform fills as controls. Results: In the phantom, enhancement during bolus arrival was greater near the lumen center than near the wall at all 11 stations and for all three boluses, whereas uniform gadolinium fills showed no such pattern. In the tube model, the two profiles produced tissue curves differing by up to 23.3% of the uniform-inlet peak and 0.30 s in time to peak for the gamma-variate input, and by 33.3% for ASL labels shorter than the fastest transit time. Their residues differed in initial amplitude and normalized temporal shape. Conclusion: Identical AIFs can produce different tissue concentration curves, depending on the spatial distributions of inlet tracer concentration and arterial flow velocity. Consequently, the residue-AIF tracer kinetic models may not be consistent with fluid mechanics or interpreted as tissue flow.
Create a lesson
Related papers
Ventilation Perfusion Functional Difference Images in Lung SPECT: a linear and symmetrical scale as an alternative to the Ventilation Perfusion Ratio
Shared title terminology · Robin de Nijs, Ronan M. G. Berg, Sofie Lindskov Hansen et al.
A Low-Cost MR-Compatible Pneumatic Motion Phantom for Magnetic Resonance Imaging
Shared title terminology · Jonathan Martin, Millie Barron, Charlotte Sappo
Quantum-walk transport oracles and amplitude estimation of a scalar range statistic in proton therapy
Shared title terminology · Kwangzoo Chung
Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation
Shared title terminology · Jianing Zhang, Jun Wang, Joseph G. Woods et al.
Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint
Shared title terminology · Andrew E. Ferretti, Emil Y. Sidky, JP Phillips et al.
Evaluation of Image Noise from Computed Tomography in an Organ-Specific Anthropomorphic Phantom
Shared title terminology · Lucas McCullum, Mojtaba Zarei, Andy Tsai et al.