Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation
Jianing Zhang, Jun Wang, Joseph G. Woods, Shaoyou Ye, Shuai Ming, Hongwei Li, Wei Hu, Wei Wei, Xiaohu Li, Thomas W. Okell, Yang Ji
Abstract
Purpose: Inter-scanner variability in cerebral blood flow (CBF) quantification limits reproducibility in multi-center arterial spin labeling (ASL) studies. We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanced perfusion imaging. Methods: A vendor-independent PCASL sequence was implemented in Pulseq and deployed on 3T scanners from Siemens, GE, and United Imaging. Seven healthy volunteers underwent single-post-labeling-delay (PLD) PCASL on all platforms, including test-retest scans. An in-house adapted Siemens vendor-based PCASL sequence served as reference. Reproducibility was assessed using within-subject coefficient of variation (CVwithin), root mean square error (RMSE), regional CBF correlation, and voxel-wise variation ratio maps. Multi-PLD PCASL and planning-free VE-PCASL were implemented as proof-of-concept extensions. Results: Mean gray matter (GM) CBF was similar across implementations. Test-retest GM CVwithin was below 4% on all platforms; Siemens-Pulseq had the lowest value (2.65%), versus 3.64% for the native sequence. GM RMSE between Siemens-Vendor and Pulseq implementations was comparable to test-retest RMSE, and all inter-scanner CVwithin values were below 3%. Voxel-wise variation ratio distributions were centered near 100%, suggesting cross-vendor variability comparable to physiological baseline fluctuations. Multi-PLD and VE-PCASL ran successfully on all platforms, yielding consistent CBF/ATT maps and vascular territory delineations. Conclusion: Pulseq-based PCASL enables vendor-agnostic perfusion imaging with low inter-scanner variability. This open-source approach provides a reproducible, standardized solution for multi-center ASL studies and facilitates deployment of advanced ASL techniques in clinical research.
Create a lesson
Related papers
EQUIP-RPT: A framework for objective evaluation of quantitative imaging methods in radiopharmaceutical therapies
Shared title terminology · Zekun Li, Carlos F. Uribe, Fereshteh Yousefirizi et al.
Quantitative Ultrasound Perfusion Biomarker: Cross-Modality Validation with Laser Speckle Imaging
Shared title terminology · Haowei Tai, Oscar Duran-Garnica, Karen Villarreal et al.
A scalar arterial input function does not uniquely determine the perfusion residue: Theory and phantom MRI
Shared title terminology · Yuyang Gan, Dominick Romano, Maneesh John et al.
Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapy
Shared title terminology · Jenneke I. de Jong, Steven J. M. Habraken, Erik W. Korevaar et al.
Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of concept
Shared title terminology · Julie Gabriel, Yvan Petit, Giuseppe Rosi et al.
Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T
Shared title terminology · Nan Yin, Marco Reisert, Theo Demerath et al.