Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T
Nan Yin, Marco Reisert, Theo Demerath, Shuai Liu, Alexander Rau, Uzay Emir, Horst Urbach, Michael Bock, Ali Caglar Özen
Abstract
Purpose: To evaluate the repeatability and cross-field-strength reproducibility (1.5T vs 3T) of in vivo cerebral myelin fraction (MF) mapping with multi-contrast dual-resolution 3D UTE (multi-UTE), and to compare it with magnetization transfer (MT)-based methods. Methods: MT methods provide an indirect myelin-sensitive measure derived from magnetization exchange between macromolecular and free-water proton pools, whereas multi-UTE targets the ultrashort-T2* signal components. In five healthy volunteers, multi-UTE and MT-based measurements were performed at 1.5T and 3T, and the calculated MF maps were compared with magnetization transfer ratio (MTR) and magnetization transfer saturation (MTsat) maps. Two volunteers underwent repeated multi-UTE measurements within and between days. Field-strength reproducibility and test-retest repeatability were evaluated using linear regression, Bland-Altman analysis, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Results: Multi-UTE enabled simultaneous acquisition of quantitative and high-resolution structural images at both 1.5T and 3T. MF repeatability was high at 3T (ICC = 0.94-0.96) and more variable at 1.5T (0,64-0.96). Across field strengths, MF and MTsat showed comparable reproducibility (CCC 0.70 vs 0.60) with small median absolute differences (8.8% vs 8.9%). MTsat showed tighter correlation (R2 = 0.77 vs 0.68), while MF showed a wider inter-regional dynamic range. MTR differed strongly between field strengths (CCC = 0.06). Conclusion: Multi-UTE MF, obtained without B1 or T1 mapping and alongside a high-resolution structural image, achieves cross-field reproducibility comparable to, but not exceeding, MTsat. Lower SNR at 1.5T and unmodelled T1 weighting may have contributed to residual field dependence.
Create a lesson
Related papers
Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapy
Jenneke I. de Jong, Steven J. M. Habraken, Erik W. Korevaar et al.
Unmyelinated axons alter the biological interpretation of MRI biomarkers of demyelination
Ali Abdollahzadeh, Ricardo Coronado-Leija, Elizabeth Chasen et al.
Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of concept
Julie Gabriel, Yvan Petit, Giuseppe Rosi et al.
Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT
Sungho Yun, Seungryong Cho
The relationship between junctional zone, smooth muscle tone and intra-uterine pressure
Nicolas R. Chevalier, Emilie Huon, Julie Poujol et al.
A Soft Sponge-Pillar Electrode Platform for Motion-Tolerant Ambulatory EEG and Sleep Monitoring
Chansoo Kim, Weilun Li, Ryan Andersen et al.