Estimation of Very High Energy Electron (VHEE) beam parameters using an in-air screen
Joel Valerian, Paul Giansiracusa, Vincent Lu, Paarangat Pushkarna, Roger Rassool, Suzie Lyn Sheehy, Yaw-Ren Eugene Tan, Matteo Volpi
Abstract
Very high energy electron (VHEE) beams offer several promising properties for radiotherapy. Accurate beam delivery requires a beam model that accounts for scattering along the beam propagation path. This work develops and validates a beam model incorporating Multiple Coulomb Scattering (MCS) to estimate beam parameters. MCS is incorporated as an additive term to the covariance matrix transformation for a drift space, allowing conventional quadrupole scans to estimate beam parameters in the presence of a downstream scatterer. The scattering correction factor is fitted to Monte Carlo (MC) simulations for a range of materials and thicknesses. The model is then validated by recovering the initial beam parameters from simulated quadrupole scans of a realistic beamline. Finally, the method is applied to in-air screen measurements at the Pulsed Energetic Electrons for Research (PEER) end station of the Australian Synchrotron. After fitting the correction factors, the mean and standard deviation of the estimation errors for the final emittance, diameter, divergence, and mean kinetic energy were (-0.06 3.17)\%, (0.15 0.66)\%, (0.18 2.18)\%, and (-0.03 0.06)\%, respectively. Simulated quadrupole scans successfully recovered the initial beam parameters, with errors of at most 13\%. PEER measurements yielded emittance estimates ranging from 0.238 to 1.753~mm\,mrad across scans, which were within the expected range. Following an initial quadrupole scan, the method allows the in-air beam size to be estimated for other quadrupole configurations. Further work is required to improve the consistency and reliability of the experimental estimates.
Create a lesson
Related papers
Experimental Assessment of Prompt Gamma Time Imaging in Complex Anatomy
Pavel Kavrigin, Alicia Garnier, Adélie André et al.
Ventilation Perfusion Functional Difference Images in Lung SPECT: a linear and symmetrical scale as an alternative to the Ventilation Perfusion Ratio
Robin de Nijs, Ronan M. G. Berg, Sofie Lindskov Hansen et al.
Emission-associated energy deposition and Cherenkov-dose proportionality in megavoltage photon beams
Xianghuan He, Yao Hao, Changyu Sun et al.
Weight-space programming for auditing clinical decision networks
Humza Nusrat, Omar Nusrat
MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection
Omar Nusrat
Influence of Geometry and Tissue Damage on the Mechanical Behaviour of Skin Meshing
Masoumeh Razaghi Pey Ghaleh, Denis O'Mahoney, Kevin Moerman