Reducing Data-Center Load Transfers with Ride-Through-Aware Voltage Control
Abstract
Fault-induced transfers of large data centers to backup supply can cause abrupt reductions in grid-served demand. Coordinating reactive-power support to mitigate these transfers requires consideration of facility-specific voltage--duration ride-through characteristics, particularly when support capacity is limited. This paper develops a ride-through-aware extension of quadratic voltage control that assesses voltage deviations relative to the admissible margins specified by these characteristics. We establish four design requirements that jointly express envelope-based severity, duration dependence, and preventive voltage-restoration incentives. Within a multiplicatively gated quadratic class, we derive necessary and sufficient conditions for satisfying these requirements and construct an explicit family of envelope-normalized objectives. We apply the proposed objectives to reactive-power coordination and evaluate their performance on the IEEE 14-bus, New England 39-bus, and NPCC 140-bus systems. Comparisons with Volt/VAR control, conventional nominal-voltage tracking, and recent data-center voltage-control methods demonstrate improved data-center retention under matched reactive-power support constraints. In the IEEE 14-bus study, the proposed controller reduces the mean data-center disconnection rate by 44.8\% and grid-demand loss by 27.4\% compared with the best-performing baseline. These results highlight the benefit of incorporating data-center ride-through requirements into reactive-power allocation.
Create a lesson
Related papers
Which Data-Center Load Models Can Be Trusted? An Evidence-Graded Review of Dynamic Modeling and Validation for Large Computational Loads
Shared title terminology · Dileep Cheerla
EMT Modeling and Coordinated Mode-Transition Ride-Through Control of Modern Data Centers
Shared title terminology · Junyuan Zheng, Salish Maharjan, Min Lwin et al.
Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation Mitigation
Shared title terminology · Quang Manh Hoang, Sina Mohammadi, Phi Long Nguyen et al.
Solver-Free and Cost-Aware Online Scheduling of AI Data Center Tasks
Shared title terminology · Xin Qin, Dawei Qiu, Fei Teng
One number per hour is not enough: directional carbon intensity of data-center ramps on the PJM fleet
Shared title terminology · Xiaoying Shi, Jinyue Yan
Open-Source Multi-Fidelity EMT Modeling of Data Center Loads for Power System Studies
Shared title terminology · Xingyu Zhao, Yingyi Tang, Junbo Zhao