Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion Collider

F. Zareef, J. J. Chwastowski, M. Pycior, I. Ahmad, W. Fryt, G. Giacomini, S. Kusyk, A. Obłąkowska-Mucha, P. Płatek, T. Polański, P. Rzeźnik, J. Swakoń, T. Szumlak, A. Tricoli, D. Wróbel

physics.ins-det

Abstract

The 20 and 30 micrometer thick Low-Gain Avalanche Detectors (LGADs) produced at Brookhaven National Laboratory (BNL) were evaluated. Detailed electrical measurements indicate well-formed and stable gain layers with consistently low leakage currents. Transient Current Technique (TCT) was used to evaluate the gain. Fast-laser timing studies demonstrate time resolutions at the level of a few tens of picoseconds. To assess operational longevity under realistic conditions for Electron-Ion Collider sub-detector systems, devices were irradiated with 30 MeV and 60 MeV protons to fluences of 1013 to 1014 neq/cm2, enabling a focused study of radiation-induced effects on gain stability and timing performance.