A novel model-based equation for size dependent mean recovery coefficients for spheres and other shapes
Abstract
Background: In NM-imaging, theoretical curves for the recovery coefficient (RC) of the signal maximum and mean are known for spheres and cubes, if a 3D Gaussian PSF is assumed. The RC of the maximum is also known for cylinders. For these and other shapes empirical equations with one or two fit-parameters have been utilized. Methods: An equation for the RC for large objects of arbitrary shape is derived and generalized into an empirical equation for smaller objects, which is verified by numerical simulations. The proposed equation is compared to published results on SPECT kidney phantom measurements and to PET measurements on the NEMA IEC PET body phantom with six spheres. Results: The signal loss (1-RC) for large spheres is inversely proportional to the radius, where the slope is proportional to the FWHM of the spatial resolution. For non-spherical shapes the generalized instead of the volume equivalent radius should be utilized. For smaller objects, an equation with one added empirical fit-parameter is presented. It is demonstrated that the EANM-guidelines' two-parameter logistic function results in a poor fit if the theoretical slope and inverse proportionality are forced and it gives a suboptimal fit when both parameters are fitted. Conclusions: A novel model-based equation for the mean RC-curve is derived. It can be used for arbitrary shapes as long as the sphericity is taken into account and it is accurate down to RC=10%. One parameter is directly related to the spatial resolution, while the other is a shape depending fit-parameter.
Create a lesson
Related papers
The influence of cold wall thickness and background activity on recovery coefficients in PET and SPECT
Shared title terminology · Robin de Nijs
Dynamic infrared thermography and computed tomography angiography fusion for DIEP flap perforator selection: a novel measurement system
Shared title terminology · Warre Clarys, Roanne Van Steen, Simon Verspeek et al.
Multi-echo AxCaliberSMT: Mapping effective axon radius from restricted diffusion and radius-dependent intra-axonal T2
Shared title terminology · Kwok-Shing Chan, Yohan Jun, Aneri Bhatt et al.
A High-Fidelity Cardiac Digital Twin for Assessing Rate-Dependent Responses: A Comparative Multi-scale Study of TT2 and Tomek Models in Stratified 3D Ventricles
Shared title terminology · Zhenyin Fu, Zhaokai Kong, Lucheng Xu et al.
Sensitivity of diffusion MRI to white matter pathology: a comparison between ROI-based effect size and TBSS analysis under different diffusion protocols, field strengths and post-processing strategies
Shared title terminology · Evgenios N. Kornaropoulos, Theodor Rumetshofer, Anna Gard et al.
Can future reirradiation justify upfront proton therapy? An extension of model-based proton therapy selection beyond primary-course NTCP benefit
Shared title terminology · Nathan Torelli, Jan Unkelbach