Characterization of a Large-Area HRPPD MCP-PMT Coupled to LYSO for TOF-PET
Yingjie Wang, Mark A. Popecki, Heejong Kim, Alexey V. Lyashenko, Stefan Cwik, Mythra Varun Nemallapudi, Jeffrey S. Souris, Michael J. Minot, Chien-Min Kao, Chin-Tu Chen
Abstract
Large-area microchannel-plate photomultipliers (MCP-PMTs) such as the High-Rate Picosecond Photon Detector (HRPPD) are attractive for time-of-flight positron emission tomography (TOF-PET). They offer excellent single-photon time resolution, low dark count rate, and large monolithic active areas. However, the coincidence time resolution (CTR) reported so far with PET scintillators falls short of expectations based upon their single-photon time resolution. We characterized a 104x104 mm HRPPD coupled to LYSO crystals and read out through a custom high-frequency amplifier. With a 2x2x3 mm LYSO crystal we measured a CTR of 107 ps full width at half maximum (FWHM) against a silicon photomultiplier (SiPM)-based reference detector. After subtracting the calibrated reference detector's contribution of 42 ps, the single HRPPD detector was found to contribute 98 ps, corresponding to 139 ps for two identical HRPPD detectors in coincidence. With clinical 3x3x20 mm crystals the CTR against the reference SiPM detector was 160 ps, corresponding to 218 ps for two identical HRPPD detectors. Timing and gain were uniform across output pads within measurement precision. Summing the four pads under a 3x3x10 mm LYSO crystal, the energy resolution for 511 keV gamma ray was 14.6% FWHM, and the 1275 keV line of the Na source was within 1% of its proportional position relative to the 511 keV peak. Flood maps resolved the individual 3 mm elements of a 4x4 array despite the 25 mm pad pitch. To the best of our knowledge the observed timing resolution improves substantially on what has been reported for large-area MCP-PMTs coupled to PET scintillators, and the crystal array identification has not been demonstrated before on such a device. These results indicate that this device class deserves renewed consideration as a photodetector technology for high-performance TOF-PET systems.
Create a lesson
Metadata
- Comments
- 8 pages, 10 figures, 3 tables. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible
Related papers
An eight-channel RFSoC waveform digitizer with AC- and DC-coupled front ends and transparent dual-DDR event memory
Shared title terminologyphysics.ins-detTao Xue
Characterization of the fast neutron response of liquid scintillator detectors at NFS
Shared title terminologyphysics.ins-detA. Pérez de Rada Fiol, G. del Río, T. Martínez et al.
Characterization of an Optical Time Projection Chamber prototype with Ar:CF_4 at atmospheric pressure
Shared title terminologyphysics.ins-detR. Felkai, M. Borysova, L. Moleri et al.
Development and Experimental Characterization of a Compact ^{228}Th--D_2O Photoneutron Source for Low-Energy Nuclear Recoil Calibration
Shared title terminologyphysics.ins-detYueqiang Tian, Yuxin Cui, Xunan Guo et al.
Development and characterization of monolithic sensors with internal gain in a 110 nm CMOS process
Shared title terminologyphysics.ins-detG. Gioachin, C. Ferrero, M. Bregant et al.
Optical characterization of microcellular PET and crystallized PEN reflectors in liquid argon for LEGEND-1000
Shared title terminologyphysics.ins-detMarta Babicz, Laura Baudis, Andreas Leonhardt et al.