Skip to content

Optimisation of gas mixture for charge and light readout with Micromegas detectors

E. Fasoula F. Benedetti, A. Bonenfant, E. Casalotti, E. Chronopoulou, E. Ferrer-Ribas, A. Giganon, Y. Giomataris, B. Moreno, T. Papaevangelou, E. C. Pollacco

physics.ins-detarXiv:2611.19860

Abstract

Optical readout of Micromegas detectors is a promising technique for neutron and charged-particle imaging, offering high spatial resolution while reducing the complexity of electronic readout. Within the framework of the development of optical-readout Micromegas detectors, different noble-gas-based mixtures have been investigated to optimize charge amplification and scintillation yield. Argon-, neon-, and helium-based mixtures with various quenchers were characterized using X-ray irradiation. The detector gain, energy resolution, and optical light intensity were measured simultaneously over a wide range of amplification fields. Unprecedented energy resolutions were achieved over a large detection area (several cm2) with He/ and Ne/ (90/10) mixtures, reaching 10.5\% and 13.3\% (FWHM), respectively, with the He-based mixture delivering particularly remarkable performance. Simultaneous charge and optical measurements further reveal that high charge gain does not necessarily translate into a strong optical response: while He- and Ne-based mixtures achieve effective charge gains of the order of 105, Ar/ mixtures produce the strongest detected light signals. Among the investigated mixtures, the ternary Ar//Isobutane (95/3/2) mixture stands out as particularly promising, combining high effective charge gain, a comparatively strong optical response, and more stable detector operation.