Skip to content

The Simons Observatory: A Novel Design for Heat Strap at Sub-Kelvin Temperatures

John Orlowski-Scherer, Oorie Desai, Daniel Lee, Nicholas Galitzki, Alex Manduca, Mark Devlin, Dominic Horne, Henry Nachman, Yuhan Wang, Edward J. Wollack

physics.ins-det

Abstract

We present a novel process for the fabrication of copper heat straps and a measurement of their thermal performance at sub-Kelvin temperatures. The conductance of the heat straps is consistent with the bulk conductivity of annealed copper over the range 60 mK to 1 K. We find no evidence for deviation from a linear dependence of conductivity with temperature over the explored range, indicating that the contact resistance at the strap ends is sub-dominant. Heat straps developed and validated through the described process have been deployed in both the Large Aperture Telescope Receiver and a Small Aperture Telescope of the Simons Observatory and have met thermal requirements.