Comment on ``Large Slip of Aqueous Liquid Flow over a Nanoengineered Superhydrophobic Surface'' by C-H Choi and C Kim
Lyderic Bocquet, Patrick Tabeling, Sebastien Manneville
Abstract
In a recent Letter (Phys. Rev. Lett. vol 96, 066001 (2006), ref [1]), Choi and Kim reported slip lengths of a few tens of microns for water on nanoengineered superhydrophobic surfaces, on the basis of rheometry (cone-and-plate) measurements. We show that the experimental uncertainty in the experiment of Ref. [1], expressed in term of slip lengths, lies in the range 20 - 100 micrometers, which is precisely the order of magnitude of the reported slip lengths. Moreover we point out a systematic bias expected on the superhydrophobic surfaces. We thus infer that it is not possible to draw out any conclusion concerning the existence of huge slip lengths in the system studied by Choi and Kim.
Create a lesson
Related papers
Nonparametric multiscale modeling of boundary lubrication: hexadecane in highly pressurized gold asperity contacts
Hannes Holey, Michael Moseler, Peter Gumbsch et al.
Asymmetric Ions in Solution are Similar to Active Brownian Particles
Setare Mostajabi Sarhangi, Dmitry V. Matyushov
Influence of twist direction and large deformation on soft material torsional contact
Yucai Hu, Pengfei Li, Michele Ciavarella et al.
Phase transitions and microphases in elastomers. II. Anisotropy-driven morphologies
Manu Mannattil, David Andelman, Haim Diamant
Comparing non-local granular fluid continuum models for silo discharge: Toward clogging prediction
Y. Zhou, Y. Wang, M. Li et al.
Residual semi-crystalline particles released during enzymatic degradation of plastics
Michael Schindler, Ludwik Leibler