Non-Compensation of the Barrel Tile Hadron Module-0 Calorimeter
Y. A. Kulchitsky, V. B. Vinogradov
Abstract
The detailed experimental information about the electron and pion responses, the electron energy resolution and the e/h ratio as a function of incident energy E, impact point Z and incidence angle Θ of the Module-0 of the iron-scintillator barrel hadron calorimeter with the longitudinal tile configuration is presented. The results are based on the electron and pion beams data for E = 10, 20, 60, 80, 100 and 180 GeV at η = -0.25 and -0.55, which have been obtained during the test beam period in 1996. The results are compared with the existing experimental data of TILECAL 1m prototype modules, various iron-scintillator calorimeters and with some Monte Carlo calculations.
Create a lesson
Related papers
Accelerating Optical Photon Simulation in DUNE with Opticks
Ilker Parmaksiz, Aaron Higuera, Laura Paulucci et al.
Search for high-mass resonances in photon-jet final states using 140 fb-1 of pp collisions at s = 13 TeV with the ATLAS detector
ATLAS Collaboration
Efficient binned profile likelihood minimization for precision measurements with RABBIT
David Walter, Josh Bendavid, Kenneth Long
A Weighting Method for Incorporating Mass Resolution Effects in Amplitude Analysis
Benhou Xiang, Wenqian Zheng, Hongxun Yang et al.
A High Performance Partial Wave Analysis Framework for Hadron Spectroscopy
Benhou Xiang, Shuangshi Fang, Beijiang Liu
Measurement of tZq inclusive and differential cross-sections in pp collisions at s = 13~TeV with the ATLAS detector
ATLAS Collaboration