Continually Working Multiwire Porous Detectors of Radiation
M. P. Lorikyan
Abstract
Performance of the known porous multiwire radiation detectors is stable in the mode of pulsed voltage supply. The results of the study of multiwire porous detector operated at constant voltage supply are presented in this article. It is shown that the detector's performance is stable, and its spatial resolution Δx β 60 μm.