Profile Monitor SEM's for the NuMI Beam at FNAL
D. Indurthy, S. Kopp, Z. Pavlovich, M. Proga
Abstract
The Neutrinos at the Main Injector (NuMI) project will extract 120 GeV protons from the FNAL Main Injector in 8.56usec spills of 4E13 protons every 1.9 sec. We have designed secondary emission monitor (SEM) detectors to measure beam profile and halo along the proton beam transport line. The SEM?s are Ti foils 5um in thickness segmented in either 1?mm or 0.5?mm pitch strips, resulting in beam loss ~5E-6. We discuss aspects of the mechanical design, calculations of expected beam heating, and results of a beam test at the 8 GeV transport line to MiniBoone at FNAL.