Frequency Scanned Interferometry for ILC Tracker Alignment
Hai-Jun Yang, Sven Nybery, Keith Riles
Abstract
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two multiple-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, measurement precision of about 50 nm was achieved for absolute distances ranging from 0.1 meters to 0.7 meters by using the first multiple-distance-measurement technique. The second analysis technique has the capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with amplitude as small as a few nanometers, without a priori knowledge. A possible optical alignment system for a silicon tracker is also presented.
Create a lesson
Related papers
Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)
B. Gerke, V. Hannen, S. Peters et al.
Beam Spill Structure Measurements at CEE Using the T0 Detector
Shuaike Lv, D. Hu, Dayu Yin et al.
CNN-based Position Reconstruction for the T0 Detector in the HIRFL-CSR External-target Experiment
Shuai-Ke Lv, D Hu, M Shao et al.
Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout
Jiawei Bian, Zaihong Yang, Qite Li et al.
Cavity Characterization for the Princeton Axion Search
Nate Otto, Jianyang Fu, Joelle-Marie Begin et al.
First demonstration of 50\,ps four-dimensional vertex reconstruction with the Timepix4 beam telescope
David Bacher, Kazu Akiba, Martin van Beuzekom et al.