Calibration of CMS calorimeters with LHC proton beam deflected by crystal
Yu. Chesnokov, V. Biryukov, V. Kryshkin
Abstract
Calibration of the forward CMS hadron calorimeters in situ by the LHC beam is proposed. Simulations show that bent crystal channeling technique is feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by 9 degrees (150 mrad) during 10 years in 1994-2004 experiments. Practical realization of calibration scheme based on simulations and previous experience is proposed.
Create a lesson
Related papers
Reconstruction of Beam Transverse Parameters in the Fermilab Side-Coupled Linac Using a Normalized Coordinate Framework
E. V. Chen, J-P. Carneiro, R. V. Sharankova et al.
Coherent collective amplification of terahertz microbunching seeded by laser frequency beating in relativistic electron beams
Wencai Cheng, Yin Kang, Kaiqing Zhang et al.
Heavy ion driven plasma wakefield acceleration with drift-like phase-shift acceleration scheme
Li Jiangdong, Xia Guoxing, Liu Jie et al.
Ultralow Mean Transverse Energy and High Quantum Efficiency Cryogenic Bialkali Photocathode for MHz-Repetition-Rate Electron Sources
D. Wang, S. Liu, J. Liu et al.
First Cobotic-Assisted String Assembly of PIP-II SSR2 Cavities at Fermilab
M. Parise, T. Aiazzi, C. Narug
PIP-II Project Progress and Challenges
O. Napoly