Skip to content

The Electronics of the H1 Lead/Scintillating-Fibre Calorimeters

H1 SpaCal Group, R. -D. Appuhn et al

physics.ins-detarXiv:physics/9812042

Abstract

The electronic system developed for the SpaCal lead/scintillating-fibre calorimeters of the H1 detector in operation at the HERA ep collider is described in detail and the performance achieved during H1 data-taking is presented. The 10 MHz bunch crossing rate of HERA puts severe constraints on the requirements of the electronics. The energy and time readout are performed respectively with a 14-bit dynamic range and with a resolution of about 0.4 ns. The trigger branch consists of a nanosecond-resolution calorimetric time-of-flight for background rejection and an electron trigger based on analog `sliding windows'. The on-line background rejection currently achieved is o(10**6). The electron trigger allows a low energy trigger threshold to be set at about 0.50 +/- 0.08 (RMS) GeV with an efficiency >99.9%. The energy and time performance of the readout and trigger electronics is based on a newly-developed low noise (sigmanoise ca. 0.4 MeV) wideband (f < 200 MHz) preamplifier located at the output of the photomultipliers which are used for the fibre light readout in the ca. 1 Tesla magnetic field of H1.

Create a lesson