PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping
Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
Abstract
Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.
Create a lesson
Metadata
- Categories
- physics.med-ph, cs.AI
Related papers
Multi-echo AxCaliberSMT: Mapping effective axon radius from restricted diffusion and radius-dependent intra-axonal T2
Shared title terminologyphysics.med-phKwok-Shing Chan, Yohan Jun, Aneri Bhatt et al.
Portable surrogate-free 4D MRI from standard fast multi-slice 2D MRI via implicit neural representations
Shared title terminologyphysics.med-phMuheng Li, Xinyang Wu, Xia Li et al.
Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence
Shared title terminologyphysics.med-phJorge Campos Pazmiño, Marc-Antoine Fortin, Véronique Fortier et al.
LesionStudio: A Patient-Informed Platform for Task-Specific Optimization of Emission Tomography Reconstruction and Analysis
Shared title terminologyphysics.med-phNarges Aghakhanolia, James Fowler, Ahmad Shariftabrizi et al.
BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction
Shared title terminologyphysics.med-phChen Cheng, Michael Ferraro, James Grover et al.
LV-CARE-Diff: A Conditional Anatomy-Aware Diffusion Model for Left Ventricular Shape Reconstruction and Function Quantification from Ultra-Sparse Cine Slices
Shared title terminologyphysics.med-phXinwang Li, Yu Lian, Bowei Liu et al.