Towards Modeling the Hemodynamic Impact of Mitral and Aortic Valve Repair in Patients with Left Ventricular Assist Devices
Mia Bonini, Michael Ferguson, Marc Hirshvogel, Maximilian Balmus, Paul C. Tang, Francis Pagani, David Nordsletten
Abstract
Valve dysfunction is a major threat to long-term success in left ventricle assist device (LVAD) therapy, with direct implications for right heart performance. In this study, we apply a patient-specific, image-based computational modeling framework to evaluate the hemodynamic impact of simulated mitral and aortic valve repair in five LVAD-supported patients. Each patient was modeled under four conditions: (patient-specific LVAD-supported state), simulated mitral valve (MV) repair, simulated aortic valve (AV) repair, and simulated combined MV&AV repair. Because validation data for valve repair were unavailable, the simulated repair scenarios are exploratory in silico interventions based on clinically validated patient-specific models. The models integrate dynamic CT imaging, echocardiography, catheterization data, and device-specific LVAD parameters into a coupled 3D-0D simulation pipeline. Valve dynamics are governed by transvalvular pressure and flow, allowing physiological modeling of regurgitant lesions and surgical repair. The right ventricular (RV) was assessed using a combination of model-derived metrics, including right ventricular ejection fraction (RVEF), pulmonary artery pulsatility index (PAPi), and RV-PA coupling. In addition, we performed blood residence time (RT) analysis to evaluate blood stasis within the left heart and aorta. The simulations suggest that valve repair improved cardiac output, reduced pulmonary congestion, and enhanced right ventricular loading conditions. Notably, mitral valve repair restored aortic valve opening during the cardiac cycle, which improved sinus washout and reduced blood residence time within the aortic root-factors associated with lower thrombotic risk. Overall, these findings suggest a potential role for valve repair in LVAD-supported hearts, though larger, validated patient cohorts are needed to confirm these results.
Create a lesson
Related papers
Quantifying the Impact of Upright Patient Positioning on Cardiac Substructures Using Deep Learning
Shared title terminology · Nicholas Summerfield, Yuhao Yan, Chase Ruff et al.
Cardiac segmentation for ventricular tachycardia radioablation and radiotherapy patients with cardiac implants
Shared title terminology · Nicholas Summerfield, Dustin Jacqmin, Chase Ruff et al.
Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation
Shared title terminology · Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
A novel vortex generator for enhancing bileaflet mechanical heart valve performance proposed through detailed hemodynamic and data-driven dynamic mode decomposition studies
Shared title terminology · A. Chauhan, C. Sasmal
How does human blood rheology influence arterial and cardiovascular device hemodynamics? A comprehensive review, discussion, and future directions
Shared title terminology · C. Sasmal
LV-CARE-Diff: A Conditional Anatomy-Aware Diffusion Model for Left Ventricular Shape Reconstruction and Function Quantification from Ultra-Sparse Cine Slices
Shared title terminology · Xinwang Li, Yu Lian, Bowei Liu et al.